IF FLEX DUCT IS RUN USE 2” THICK INDUSTRIAL GRADE FLEX AND INDUSTRIAL GRADE DUCT TAPE FOR THE JOINTS

INSTALL BACK DRAFT DAMPERS AS CLOSE AS POSSIBLE TO THE INTERIOR REGISTERS - [ SUPPLY AND RETURN.]  FAILURE TO DO SO MAY CAUSE NIGHT TIME CYCLING IN REVERSE.

SPACE HEAT ONLY SYSTEMS MUST BE MOUNTED IN THE VERTICAL POSITION OR COVERED IN THE SUMMER TO PREVENT OVER HEATING.

USE ONLY HIGH TEMPERATURE SILICONE [400 *F] TO JOIN THE SYSTEM COLLECTORS TOGETHER. FAILURE TO USE HIGH TEMPERATURE SILICONE [400 *F] MAY LEAD TO JOINT FAILURE AND CREATE A COMBUSTIBLE SITUATION!

PUSHING AIR INTO THE  COLLECTOR INSTEAD OF PULLING IT OUT MAY DAMAGE THE COLLECTOR PLATE AND CREATE POTENTIAL JOINT FAILURE !

PUT SUPPLY AND RETURN REGISTERS AT OPPOSITE ENDS OF THE BUILDING IF POSSIBLE TO PREVENT SHORT CYCLING IN THE SYSTEM. RUN THE SUPPLY TO THE NORTH END OF THE BUILDING WHEN POSSIBLE.